The 220DD Baratron® differential capacitance manometer is temperature controlled to 45°C for use in demanding, harsh environments. The Baratron® 220 includes all signal conditioning, power supply and is enclosed in a rugged, NEMA1 approved housing. It is available in ranges from 1 to 25,000 mmHg/Torr (500 psia). Accuracy is ±0.15% of Reading.
Compare | Description | Drawings, CAD & Specs | Availability | Price | |||
---|---|---|---|---|---|---|---|
![]() |
Vacuum Pressure Transducer, Differential, 1 Torr, 0.5 in. Tube, NEMA1, 45C
$2,663.00
|
220DD-00001A2B Vacuum Pressure Transducer, Differential, 1 Torr, 0.5 in. Tube, NEMA1, 45C | $2,663.00 |
|
|||
![]() |
220DD-00001B2B Vacuum Pressure Transducer, Differential, 1 Torr, 8 VCR, NEMA1, 45C | $2,866.00 |
|
||||
![]() |
Vacuum Pressure Transducer, Differential, 1 Torr, NW16 ISO-KF, NEMA1, 45C
$2,866.00
|
220DD-00001D2B Vacuum Pressure Transducer, Differential, 1 Torr, NW16 ISO-KF, NEMA1, 45C | $2,866.00 |
|
|||
![]() |
Vacuum Pressure Transducer, Differential, 10 Torr, 0.5 in. Tube, NEMA1, 45C
$2,663.00
|
220DD-00010A2B Vacuum Pressure Transducer, Differential, 10 Torr, 0.5 in. Tube, NEMA1, 45C | $2,663.00 |
|
|||
![]() |
220DD-00010B2B Vacuum Pressure Transducer, Differential, 10 Torr, 8 VCR, NEMA1, 45C | $2,866.00 |
|
||||
![]() |
Vacuum Pressure Transducer, Differential, 10 Torr, NW16 ISO-KF, NEMA1, 45C
$2,866.00
|
220DD-00010D2B Vacuum Pressure Transducer, Differential, 10 Torr, NW16 ISO-KF, NEMA1, 45C | $2,866.00 |
|
|||
![]() |
Vacuum Pressure Transducer, Differential, 100 Torr, 0.5 in. Tube, NEMA1, 45C
$2,663.00
|
220DD-00100A2B Vacuum Pressure Transducer, Differential, 100 Torr, 0.5 in. Tube, NEMA1, 45C | $2,663.00 |
|
|||
![]() |
220DD-00100B2B Vacuum Pressure Transducer, Differential, 100 Torr, 8 VCR, NEMA1, 45C | $2,866.00 |
|
||||
![]() |
Vacuum Pressure Transducer, Differential, 100 Torr, NW16 ISO-KF, NEMA1, 45C
$2,866.00
|
220DD-00100D2B Vacuum Pressure Transducer, Differential, 100 Torr, NW16 ISO-KF, NEMA1, 45C | $2,866.00 |
|
The following options are available for 220DD Baratron® Differential Pressure Transducers
Ordering Code Example: 220DD00100A2B
Configuration Option | Option Code |
---|---|
220DD Differential Capacitance Manometer | 220DD |
Range Full Scale | |
1 Torr | 00001 |
10 Torr | 00010 |
20 Torr | 00020 |
100 Torr | 00100 |
1000 Torr | 01000 |
5000 Torr | 05000 |
10000 Torr | 10000 |
15000 Torr | 15000 |
20000 Torr | 20000 |
25000 Torr | 25000 |
Fittings | |
0.5 in. OD tube | A |
8 VCR female | B |
1.33 in. OD CF, rotatable | C |
NW16 ISO-KF | D |
Power Requirements | |
115/230 VAC | 2 |
Analog Output | |
0-10 VDC and 4-20 mA | B |