Show Filters:
Showing 6 of 6 total products
Compare Description Drawings, CAD & Specs Avail. Price
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers226B11TCDCDFB2A1Vacuum Pressure Transducer, Differential, 10 Torr, 4 VCR-F, 0-10 VDC, Bidirectional, DB9
$943
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers226B12KBGBGFU3T1Pressure Transducer, Differential, 100 kPa, 0.1875 in. Tube, 0-5 VDC, Unidirectional, Terminal
$981
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers226B12TCDCDFB2A1Vacuum Pressure Transducer, Differential, 100 Torr, 4 VCR-F, 0-10 VDC, Bidirectional, DB9
$943
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers226B13TCDCDFB2A1Pressure Transducer, Differential, 1000 Torr, 4 VCR-F, 0-10 VDC, Bidirectional, DB9
$943
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers226B13TCDCDFB4T1Pressure Transmitter, Differential, 1000 Torr, 4 VCR-F, 4-20 mA, Bidirectional, Terminal
$983
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers226B21MGAGAFB1T1Vacuum Pressure Transducer, Differential, 20 mbar, NW16 ISO-KF, 0-1 VDC, Bidirectional, Terminal
$981

Configuration Options

The following options are available for the 226B Baratron® Differential Capacitance Manometer.
Ordering Code Example: 226BXXXYYZZQSSTV

Configuration Option Option Code
226B Baratron Differential Capacitance Manometer 226B
Pressure Range
0.02 (kPA only) U2
0.1 (kPA & inH2O only) .1
0.2 (not available inH2O) .2
0.5 (kPA & inH2O only) .5
1 01
2 02
5 05
10 11
20 21
50 (not available for kPA) 51
100 12
200 (not available for kPA & inH2O) 22
500 (inH2O only) 52
1000 (not available for kPA & inH2O) 13
Engineering Units
Torr/mmHg T
mbar M
kPa K
inH2O W
cmH2O R
Reference Side Fitting (compatible with)
0.25 in. OD tube BB
0.1875 in. OD tube BG
4 male VCR CB
4 female VCR CD
4 male VCO DC
4 female VCO DD
0.25 in. female NPT FA
0.25 in. male NPT FB
0.125 in. male NPT FE
0.125 in. female NPT FF
NW16 KF GA
1.33 in. OD Conflat HA
Measurement Side Fitting (compatible with)
0.25 in. OD tube BB
0.1875 in. OD tube BG
4 male VCR CB
4 female VCR CD
4 male VCO DC
4 female VCO DD
0.25 in. female NPT FA
0.25 in. male NPT FB
0.125 in. male NPT FE
0.125 in. female NPT FF
NW16 KF GA
1.33 in. OD Conflat HA
Accuracy
0.50% Full Scale (standard) F
0.30% Full Scale K
0.30% Reading (unidirectional calibrations only) S
Input/Output & Calibration
±15 VDC input/0-1 VDC bidirectional output B1
±15 VDC input/0-10 VDC bidirectional output B2
±15 VDC input/0-5 VDC bidirectional output B3
+24-32 VDC excitation/4-20 mA bidirectional output B4
+24 VDC input/0-1 VDC bidirectional output B5
+24 VDC input/0-5 VDC bidirectional output B7
±15 VDC input/0-1 VDC unidirectional output U1
±15 VDC input/0-10 VDC unidirectional output U2
±15 VDC input/0-5 VDC unidirectional output U3
+24-32 VDC excitation/4-20 mA unidirectional output U4
+24 VDC input/0-1 VDC unidirectional output U5
+24 VDC input/0-5 VDC unidirectional output U7
Electrical Connector
9-pin D-subminiature (standard) A
Terminal block adaptor, 5-post T
Flying lead adapter, 10 ft (3 m) length L
Mounting
No bracket 0
Mounting bracket, standard 1
Mounting bracket, slotted 2
Description
226B Baratron® 0.2-1000 Torr Differential Capacitance Manometers

226B

Differential Capacitance Manometer, 226A Series

Specifications

  • Type
    Vacuum/pressure Transducer
  • Measurement Type
    Differential
  • Full Scale Pressure Ranges
    0.2, 1, 2, 5, 10, 20, 50, 100, 200, and 1000 Torr and equivalents in kPa, mbar, inches H2O, and cm H2O
  • Output Signal
    0-1VDC, 0 - 5VDC, 0-10VDC > 10 k Ω load; or 2-wire 4-20 mA from +24VDC supply into < 500 Ω load
  • Fitting Type
    Standard: 0.25 in. OD (6.4 mm) tubes
    Optional: Various
  • Electrical Connector
    9-pin D-subminiature standard, terminal block and flying leads optional
  • Resolution
    0.01% of Full Scale
  • Accuracy
    0.50% of Full Scale unidirectional or bidirectional standard; 0.30% of Full Scale unidirectional or bidirectional, and 0.30% of Reading (unidirectional calibrations only)
  • Zero Temperature Coefficient
    0.1% Full Scale/°C for standard accuracy specification
  • Span Temperature Coefficient
    0.04% of Reading/°C
  • Sensor Internal Volume
    Measurement Side (Px): 1.4 cm
    Reference Side (Pr): 9.0 cm
    (when equipped with standard 1/4-inch (6.4 mm) O.D. inlet and reference tubes)
  • Ambient Operating Temperature
    0-50°C
  • Maximum Overpressure
    Measurement Side (Px): 120% of Full Scale or 20 psi (140 kPa), whichever is higher
    Reference Side (Pr): 120% of Full Scale
  • Maximum Line Pressure
    40 psig (275 kPa)
  • Exposed Materials
    Measurement Side (Px): Inconel
    Reference Side (Pr): Inconel, ceramic, palladium, stainless steel, glass
  • Power Requirements
    ±15 VDC (±5%) or +13 VDC to +30 VDC @ 25 mA, ripple less than 20 mV
  • Compliance
    CE, SEMI S2

Features

Baratron® Capacitance Manometer Technology

Capacitance manometer sensor schematic showing the internal components

Capacitance manometers are electro-mechanical gauges that can measure both pressure and vacuum. The capacitance gauge translates a pressure-modulated movement in a thin diaphragm into an electrical signal proportional to the pressure. The pressure sensor is the thin diaphragm that is exposed to the pressure or vacuum being measured via the inlet tube. An electrode is mounted in the reference cavity behind the diaphragm. Pressure differences between the process and the reference cavity deflect the diaphragm slightly, changing the distance between it and the electrode. Variations in this distance produce variations in the capacitance between the diaphragm and the electrode creating an electrical signal that is proportional to the pressure change. Since differences in the capacitance signal are produced by physical changes within the manometer and not by changes in the gas properties, pressure measurements by the capacitance manometer are independent of the composition of the gas being measured.

Differential Pressure Measurement

Differential capacitance manometers can be connected to any pressure or vacuum source for use as the reference pressure. These manometers read the difference in pressure between the inlet tube and the reference cavity at the backside of the electrode. Differential pressure transducers can be used to measure either the true differential pressure or vacuum between two locations, or the reference side of the product can be left open to provide a true reference to local atmospheric pressure. Applications include air and gas flow measurements for filters and analytical systems, downstream pressure control in thin film processing systems, and automated leak testing systems.

Inconel® Nickel Alloy Construction

The patented capacitance sensor is built entirely from Inconel® nickel alloys on its measurement side, which offers superior corrosion resistance over long periods of time. Inconel® construction also offers high overpressure tolerances that reduce errors due to line pressure spikes, and high burst pressure ratings that contribute to overall system safety.

Wide Variety of Proportional Analog Outputs

226 & 228 differential capacitance manometers provide a high-level analog output signal that is linear with pressure. It can operate on either ±15VDC or +24VDC input voltage, and it offers four different analog output signals (0-10V, 0-5V, 0-1V, and 4-20 mA) for use in nearly any control or data acquisition system. The sensor and electronics are mounted in a rugged industrial-grade housing that has high immunity and isolation from RF and EM interference.

Twelve Different Fitting Types

These Baratron® differential capacitance manometers can be equipped with any of twelve (12) different fittings on either the measurement or reference sides, including common industrial and semiconductor-industry standards like VCR®, NW-KF, VCO®, and NPT.

Accessories

Compatible Cables

Compare Description Drawings, CAD & Specs Avail. Price
RCB226S-1-M1
$420
RCB226S-3-10
$229
RCB226S-2-10
$263

Power Supplies and Displays

Compare Description Drawings, CAD & Specs Avail. Price
pr4000b digital power supply and readoutPR4000BF2V2
$2,982
pr4000b digital power supply and readoutPR4000BF2V3
$3,033
pr4000b digital power supply and readoutPR4000BF5V2
$2,785
pr4000b digital power supply and readoutPR4000BS2V2
$2,706
pr4000b digital power supply and readoutPR4000BS2V3
$2,729
pr4000b digital power supply and readoutPR4000BF5V3
$2,785
pdr2000a two-channel digital power supply and readoutPDR2000AO
$999