Compare Description Drawings, CAD & Specs Avail. Price
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00001AAAbsolute Pressure Switch, 1 Torr, 0.5 in. Tube, Standard DPDT Relay
$774
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00001ABAbsolute Pressure Switch, 1 Torr, 0.5 in. Tube, Fail Safe DPDT Relay
$774
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00001BAAbsolute Pressure Switch, 1 Torr, 8 VCR Female, Standard DPDT Relay
$876
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00001BBAbsolute Pressure Switch, 1 Torr, 8 VCR Female, Fail Safe DPDT Relay
$876
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00001DAAbsolute Pressure Switch, 1 Torr, ISO-KF, Standard DPDT Relay
$876
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00001DBAbsolute Pressure Switch, 1 Torr, NW16 ISO-KF, Fail Safe DPDT Relay
$876
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00010AAAbsolute Pressure Switch, 10 Torr, 0.5 in. Tube, Standard DPDT Relay
$774
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00010ABAbsolute Pressure Switch, 10 Torr, 0.5 in. Tube, Fail Safe DPDT Relay
$774
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00010BAAbsolute Pressure Switch, 10 Torr, 8 VCR Female, Standard DPDT Relay
$876
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches141AA-00010BBAbsolute Pressure Switch, 10 Torr, 8 VCR Female, Fail Safe DPDT Relay
$876

Configuration Options

The following options are available for the 141 Baratron® Vacuum Pressure Switch.
Ordering Code Example: 141AA-00001A

Configuration Option Option Code
141 Vacuum Pressure Switch 141AA
Full Scale Range
1 Torr 00001
2 Torr 00002
10 Torr 00010
100 Torr 00100
1000 Torr 01000
Fittings
1/2 in. OD Tube A
Swagelok 8 VCR female B
Mini-CF, rotatable C
NW16 ISO-KF D
Swagelok 8 VCO female E
Relay Mode
Standard operation (energizes above set point) A
Fail-safe operation (energizes below set point) B
Description
141A 0.1-1000 Torr Baratron® Absolute Pressure Switches

141A

Absolute Pressure Switch, 1 - 1000 Torr, Unheated, Relay Output

Specifications

  • Type
    Pressure Switch
  • Measurement Type
    Absolute
  • Full Scale Pressure Ranges
    1, 2, 10, 100, 1000 Torr (mmHg) absolute
  • Set Point Range
    0.2% to 100% of Full Scale
  • Sensor Temperature
    Ambient
  • Accuracy
    ±0.5% of Full Scale Range (± temperature coefficients)
  • Zero Temperature Coefficient
    ±0.04% of Full Scale/°C
  • Span Temperature Coefficient
    ±0.06% of set point/°C
  • Operating Temperature Range
    0° to 50°C
  • Response Time
    < 20 msec from 0 to Full Scale
  • Relay Contact Ratings
    DPDT, 2 amps @ 30 VDC or 1 amp @ 120 VAC resistive
  • Internal Volume
    7.0 cc (5K-25K Torr units have an 8.5 cc volume)
  • Overpressure
    120% of Full Scale or 35 psia (1000 mmHg), whichever is larger (1 and 2 Torr Full Scale units have a max. overpressure of 25 psia)
  • Power Requirements
    20 to 30 VDC, 72 mA
  • Compliance
    Compliant to EMC Directive 2014/30/EU

Features

Baratron® Capacitance Manometer Technology

Capacitance manometer sensor schematic showing the internal components

Capacitance manometers are electro-mechanical gauges that can measure both pressure and vacuum. The capacitance gauge translates a pressure-modulated movement in a thin diaphragm into an electrical signal proportional to the pressure. The pressure sensor is the thin diaphragm that is exposed to the pressure or vacuum being measured via the inlet tube. An electrode is mounted in the reference cavity behind the diaphragm. Pressure differences between the process and the reference cavity deflect the diaphragm slightly, changing the distance between it and the electrode. Variations in this distance produce variations in the capacitance between the diaphragm and the electrode creating an electrical signal that is proportional to the pressure change. Since differences in the capacitance signal are produced by physical changes within the manometer and not by changes in the gas properties, pressure measurements by the capacitance manometer are independent of the composition of the gas being measured.

Fully Adjustable Set Point

The high accuracy set point can be adjusted from from 0.2% to 100% of Full Scale for tripping the switches relay. An LED provides visual ''above set point'' indication, and facilitates adjustment of the set point.

Inconel® and Stainless Steel Construction

The dual electrode sensor is an all-metal, all-welded design, thus exposing only corrosion-resistant Inconel® and stainless steel to the process gases.

Absolute Pressure Switching

The 141A and 142A pressure switches are referenced to vacuum for absolute pressure trip point switching. Applications for absolute pressure switches include soft pumping, gas box switching, and safety interlocks.

DPDT Relay

A double pole double throw relay rated at 2 amps @ 30 VDC or 1 amp @ 120 VAC resistive provides the set point switching. The relay is energized when pressure is above set point. Fail-safe operation provides for the relay to be energized when pressure is below set point.

Accessories

Power Supplies and Displays

Compare Description Drawings, CAD & Specs Avail. Price
pr4000b digital power supply and readoutPR4000BF5V3
$2,785
pr4000b digital power supply and readoutPR4000BF2V3
$3,033
pr4000b digital power supply and readoutPR4000BF5V2
$2,785
pr4000b digital power supply and readoutPR4000BS2V2
$2,706
pr4000b digital power supply and readoutPR4000BF2V2
$2,982
pr4000b digital power supply and readoutPR4000BS2V3
$2,729
pdr2000a two-channel digital power supply and readoutPDR2000AO