The 625H Absolute Capacitance Manometer features two user adjustable process trip point relays, each with an adjustment range from 0.1% to 100% of Full Scale or voltage equivalent 0.01 to 10 VDC. Dual color LEDs indicate relay status. It is temperature controlled at 100°C, and is available in full scale ranges of 1, 10, 20, 100, 500, and 1000 Torr.
- Temperature controlled to 100°C for 0.25% of reading accuracy
- 0 to 10 VDC analog output proportional to absolute pressure
- Two adjustable process trip point relays
- Measures total pressure directly, independent of gas composition
- Inconel® sensor for corrosion resistance
- Integrated sump provides particle protection See All Features
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | 625H01TCEEBHeated Capacitance Manometer, 1 Torr, 100°C, 8 VCR-F, DB15 w/Thread Lock, 0-10 VDC, 2 Relays | |||||
![]() | 625H01TCEEUHeated Capacitance Manometer, 1 Torr, 100°C, 8 VCR-F, Terminal Block, 0-10 VDC, 2 Relays | |||||
![]() | 625H01TGAEBHeated Capacitance Manometer, 1 Torr, 100°C, NW16 ISO-KF, DB15 w/Thread Lock, 0-10 VDC, 2 Relays | |||||
![]() | 625H01TGAEUHeated Capacitance Manometer, 1 Torr, 100°C, NW16 ISO-KF, Terminal Block, 0-10 VDC, 2 Relays | |||||
![]() | 625H11TCEEBHeated Capacitance Manometer, 10 Torr, 100°C, 8 VCR-F, DB15 w/Thread Lock, 0-10 VDC, 2 Relays | |||||
![]() | 625H11TCEEUHeated Capacitance Manometer, 10 Torr, 100°C, 8 VCR-F, Terminal Block, 0-10 VDC, 2 Relays | |||||
![]() | 625H11TGAEBHeated Capacitance Manometer, 10 Torr, 100°C, NW16 ISO-KF, DB15 w/Thread Lock, 0-10 VDC, 2 Relays | |||||
![]() | 625H11TGAEUHeated Capacitance Manometer, 10 Torr, 100°C, NW16 ISO-KF, Terminal Block, 0-10 VDC, 2 Relays | |||||
![]() | 625H12TCEEBHeated Capacitance Manometer, 100 Torr, 100°C, 8 VCR-F, DB15 w/Thread Lock, 0-10 VDC, 2 Relays | |||||
![]() | 625H12TCEEUHeated Capacitance Manometer, 100 Torr, 100°C, 8 VCR-F, Terminal Block, 0-10 VDC, 2 Relays |
Configuration Options
The following options are available for 625H Baratron® Heated Absolute Capacitance Manometers
Ordering Code Example: 625H11TBAEB
| Configuration Option | Option Code |
|---|---|
| 625H Absolute Capacitance Manometer. | 625H |
Full Scale Range |
|
| 1 Torr | 01T |
| 10 Torr | 11T |
| 20 Torr | 21T |
| 100 Torr | 12T |
| 500 Torr | 52T |
| 1000 Torr | 13T |
Fittings |
|
| 0.5 in. OD Tube | BA |
| 8 VCR | CE |
| Mini-CF | HA |
| NW16 ISO-KF | GA |
| NW16 ISO-KF, right angle | GE |
| NW25 ISO-KF | GC |
Accuracy |
|
| 0.25% of Reading | E |
Connector |
|
| 15 pin Type "D" with Thread Locks | B |
| 15 pin Type "D" with Slide Locks | P |
| Terminal Block Adapter | U |
| 15 pin Type "D" Filtered | V |
Specifications
- TypeVacuum/pressure Transducer
- Measurement TypeAbsolute
- Sensor TemperatureControlled to 100°C
- Full Scale Pressure Ranges1, 10, 20, 100, 1000 Torr
- Accuracy0.25% of Reading
- Resolution0.001% of Full Scale
- Analog Output0-10 VDC into > 10K Ω load
- Zero Temperature Coefficient0.002% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Ambient Operating Temperature15-50°C
- Volume6.3 cc
- Warm-up Time2 hours
- Overpressure Limit45 psia (310 kPa)
- Exposed MaterialsInconel®
- Power Requirements±15 VDC ±5% @ 0.60 Amps (max.)
- Trip Points2
- Trip Point Level Signal0.01-10 VDC for each trip point
- Output RelaysSPDT, 1 Amp @ 30 VDC or 0.5 Amp @ 30 VAC resistive
- ComplianceFully compliant to EMC Directive 2004/108/EC
Fully compliant to Directive 2002-95-EC
Features
Baratron® Capacitance Manometer Technology
Capacitance manometers are electro-mechanical gauges that can measure both pressure and vacuum. The capacitance gauge translates a pressure-modulated movement in a thin diaphragm into an electrical signal proportional to the pressure. The pressure sensor is the thin diaphragm that is exposed to the pressure or vacuum being measured via the inlet tube. An electrode is mounted in the reference cavity behind the diaphragm. Pressure differences between the process and the reference cavity deflect the diaphragm slightly, changing the distance between it and the electrode. Variations in this distance produce variations in the capacitance between the diaphragm and the electrode creating an electrical signal that is proportional to the pressure change. Since differences in the capacitance signal are produced by physical changes within the manometer and not by changes in the gas properties, pressure measurements by the capacitance manometer are independent of the composition of the gas being measured.
Internally Heated to 100°C
These capacitance manometers are temperature controlled to 100°C for improved accuracy. Unheated versions are exposed to ambient temperature variations which can degrade the sensor accuracy. These devices have the sensor enclosed in a volume that is maintained at a constant temperature above ambient. This solution improves the manometer’s accuracy and repeatability and lowers instrument drift by reducing or eliminating process contamination within the manometer. Heated manometers are recommended for applications that require maximum accuracy and repeatability, operate above ambient temperature and for those processes that employ hot gases.
Absolute Pressure Measurement
These Baratron® pressure transducers are referenced to vacuum for absolute pressure measurement. Applications include: vacuum furnaces, freeze-drying of fruits and vegetables, gas lasers, automotive component testing, bottle coatings, and vacuum distillation.
All-Inconel® Wetted Surfaces
These pressure transducers feature all Inconel® construction of the pressure sensor allowing it to operate without damage in virtually any chemical environment, including exposure to halogens, deionized water and steam, and ozone.
0 to 10 VDC Proportional Analog Output
These Baratron® capacitance manometers feature a high-level 0-10 VDC analog output signal that is linear with pressure. This analog output can be interfaced with an MKS pressure controller, an MKS power supply/display instrument, or any instrument that meets these requirements.
Two Adjustable Process Trip Point Relays
These absolute capacitance manometers features two user adjustable process trip point relays, each with an adjustment range from 0.1% to 100% of Full Scale or voltage equivalent 0.01 to 10 VDC. Dual color LEDs indicate relay status. Typical relay uses include pump cross-over and valve activation.
Type "D" Pin-Out Assignments
| Pin | Description |
|---|---|
| 1 | Trip Point-A V-level |
| 2 | First Pressure Output |
| 3 | Trip Point-A N.C. |
| 4 | Trip Point-A N.O. |
| 5 | Power Common |
| 6 | -15 VDC |
| 7 | +15 VDC |
| 8 | Trip Point-A Common |
| 9 | Trip Point-B N.O. |
| 10 | Trip Point-B N.C. |
| 11 | Trip Point-B Common |
| 12 | Pressure Output Return |
| 13 | Trip Point-B V-Level |
| 14 | No Connection |
| 15 | Chassis Ground |
Accessories
Compatible Cables
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | RCB473S-1-10 | |||||
![]() | RCB259S-5-10 |
Power Supplies and Displays
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | AS11900G-03 | |||||
![]() | PR4000BF2V2 | |||||
![]() | PR4000BF2V3 | |||||
![]() | PR4000BF5V2 | |||||
![]() | PR4000BS2V2 | |||||
![]() | PR4000BS2V3 | |||||
![]() | PR4000BF5V3 | |||||
![]() | PDR2000AO |
Resources
Literature
625H Heated (100°C) Absolute Baratron® Capacitance Manometer with Trip Points(1.6 MB, PDF) Analog 600 Series Absolute Baratron® Capacitance Manometer Selection Guide(2.9 MB, PDF)
Manuals
MKS 624H & 625H Transducers Manual(804.6 kB, PDF) 624 & 625 Capacitance Manometer Pin-outs(23.5 kB, PDF)









