Overview
The 226B12KBGBGFU3T1 Baratron® differential capacitance manometer is ranged for 100 kPA, has 3/16 inch OD reference and measurement side tubes, 0.50% of Full Scale accuracy, ±15 VDC input, 0 - 5 VDC analog output with unidirectional calibration, a 5-post terminal block adapter electrical connector and a standard mounting bracket. It is mounted in a rugged industrial-grade housing that minimizes external RF/EM interference on the electronics and when properly configured, is completely "drop-in" compatible with earlier Baratron® differential manometers.
Technical Specs
- TypeVacuum/pressure Transducer
- Measurement TypeDifferential
- Full Scale Range100 kPa
- Analog Output0-5 VDC
- CalibrationUnidirectional
- Electrical Connector5-pin Terminal block adapter
- Resolution0.01% of Full Scale
- Accuracy0.50% of Full Scale
- Zero Temperature Coefficient0.1% Full Scale/°C for standard accuracy specification
- Span Temperature Coefficient0.04% of Reading/°C
- Sensor Internal VolumeMeasurement Side: 1.4 cm3, Reference Side: 9.0 cm3
- Operating Temperature Range0-50°C
- Maximum OverpressureMeasurement Side: 120% of Full Scale or 20 psi (140 kPa), whichever is higher, Reference Side: 120% of Full Scale
- Maximum Line Pressure40 psig (275 kPa)
- Exposed MaterialsMeasurement Side: Inconel, Reference Side: Inconel, ceramic, palladium, stainless steel, glass
- Measurement Side Fitting0.1875 in. OD tube
- Reference Side Fitting0.1875 in. OD tube
- Mounting BracketStandard
- Trip Points1
- Power Requirements±15 VDC
- ComplianceCE, SEMI S2-0706
Technical Specs
- TypeVacuum/pressure Transducer
- Measurement TypeDifferential
- Full Scale Range100 kPa
- Analog Output0-5 VDC
- CalibrationUnidirectional
- Electrical Connector5-pin Terminal block adapter
- Resolution0.01% of Full Scale
- Accuracy0.50% of Full Scale
- Zero Temperature Coefficient0.1% Full Scale/°C for standard accuracy specification
- Span Temperature Coefficient0.04% of Reading/°C
- Sensor Internal VolumeMeasurement Side: 1.4 cm3, Reference Side: 9.0 cm3
- Operating Temperature Range0-50°C
- Maximum OverpressureMeasurement Side: 120% of Full Scale or 20 psi (140 kPa), whichever is higher, Reference Side: 120% of Full Scale
- Maximum Line Pressure40 psig (275 kPa)
- Exposed MaterialsMeasurement Side: Inconel, Reference Side: Inconel, ceramic, palladium, stainless steel, glass
- Measurement Side Fitting0.1875 in. OD tube
- Reference Side Fitting0.1875 in. OD tube
- Mounting BracketStandard
- Trip Points1
- Power Requirements±15 VDC
- ComplianceCE, SEMI S2-0706