Show Filters:
Showing 10 of 10 total products
Compare Description Drawings, CAD & Specs Avail. Price
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D01TBEAbsolute Pressure Transducer, 1 Torr, 0-10 VDC, 8 VCR-F, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D01TDEAbsolute Pressure Transducer, 1 Torr, 0-10 VDC, NW16 ISO-KF, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D02TBEAbsolute Pressure Transducer, 2 Torr, 0-10 VDC, 8 VCR-F, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D02TDEAbsolute Pressure Transducer, 2 Torr, 0-10 VDC, NW16 ISO-KF, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D11TBEAbsolute Pressure Transducer, 10 Torr, 0-10 VDC, 8 VCR-F, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D11TDEAbsolute Pressure Transducer, 10 Torr, 0-10 VDC, NW16 ISO-KF, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D12TBEAbsolute Pressure Transducer, 100 Torr, 0-10 VDC, 8 VCR-F, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D12TDEAbsolute Pressure Transducer, 100 Torr, 0-10 VDC, NW16 ISO-KF, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D13TBEAbsolute Pressure Transducer, 1000 Torr, 0-10 VDC, 8 VCR-F, 15-pin D-sub
$1,460
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers626D13TDEAbsolute Pressure Transducer, 1000 Torr, 0-10 VDC, NW16 ISO-KF, 15-pin D-sub
$1,460

Configuration Options

The following options are available for 626D Baratron® Absolute Capacitance Manometers
Ordering Code Example: 626DXXXYZ

Configuration Option Option Code
626D Absolute Capacitance Manometer 626D
Full Scale Range
0.1 Torr .1T
0.25 Torr RET
1 Torr 01T
2 Torr 02T
10 Torr 11T
20 Torr 21T
100 Torr 12T
500 Torr 52T
1000 Torr 13T
Fittings
0.5 in. (12.7 mm) OD tube A
8 female VCR B
1.33 in. OD (33.8 mm) Conflat, rotatable C
NW16 ISO-KF D
8 female VCO E
NW25 ISO-KF Q
Accuracy
0.25% Reading (1 to 1000 Torr) - standard E
0.15% Reading (10 to 1000 Torr) - optional D
0.50% of Reading (< 1 Torr) - standard F
Description
626D 0.1-1000 Torr, Unheated Absolute Baratron® Capacitance Manometers

626D

Analog Capacitance Manometer, 0.1 - 1,000 Torr, 15-pin D-sub Connector

Specifications

  • Type
    Vacuum/pressure Transducer
  • Measurement Type
    Absolute
  • Full Scale Pressure Ranges
    0.1, 0.25, 1, 2, 10, 20, 100, 500, or 1000 Torr and metric equivalents
  • Sensor Temperature
    Ambient
  • Analog Output
    0-10 VDC into > 10 kΩ load
  • Electrical Connector
    15-pin D-subminiature
  • Zero Temperature Coefficient
    0.005% FS/°C for 10 to 1000 Torr ranges
    0.010% FS/°C for 2 Torr range
    0.015% FS/°C for 1 Torr range
    0.020% FS/°C for ranges < 1 Torr
  • Span Temperature Coefficient
    0.04% of Reading/°C
  • Operating Temperature Range
    0-50°C
  • Resolution
    0.001% of Full Scale
  • Volume
    6.3 cm³
  • Overpressure Limit
    45 psia (310 kPa)
  • Exposed Materials
    Inconel® and Incoloy® nickel alloys
  • Power Requirements
    ±15 VDC (±5%) @ 35 mA
  • Compliance
    CE compliant to EMC Directive 2004/108/EC

Features

Baratron® Capacitance Manometer Technology

Gas independent pressure measurement with a Baratron® capacitance manometer. Schematic shows the internal components and functional zones.

Capacitance manometers are electro-mechanical gauges that can measure both pressure and vacuum. The capacitance gauge translates a pressure-modulated movement in a thin diaphragm into an electrical signal proportional to the pressure. The pressure sensor is the thin diaphragm that is exposed to the pressure or vacuum being measured via the inlet tube. An electrode is mounted in the reference cavity behind the diaphragm. Pressure differences between the process and the reference cavity deflect the diaphragm slightly, changing the distance between it and the electrode. Variations in this distance produce variations in the capacitance between the diaphragm and the electrode creating an electrical signal that is proportional to the pressure change. Since differences in the capacitance signal are produced by physical changes within the manometer and not by changes in the gas properties, pressure measurements by the capacitance manometer are independent of the composition of the gas being measured.

Percent of Reading Accuracy

Accuracy is specified as a percent of Reading, not Full Scale, as seen in some of the lower performance devices. Percent of Reading accuracy provides you with an even more accurate output signal in the lower scale of the pressure range, where it is needed most.

Absolute Pressure Measurement

These Baratron® pressure transducers are referenced to vacuum for absolute pressure measurement. Applications include: vacuum furnaces, freeze-drying of fruits and vegetables, gas lasers, automotive component testing, bottle coatings, and vacuum distillation.

Inconel® and Incoloy® Construction

These pressure transducers feature Inconel® and Incoloy® nickel alloy construction of the pressure sensor allowing it to operate without damage in virtually any chemical environment, including halogens, deionized water and steam, and ozone. The sensor is fully welded with no intermediate brazing or joining materials.

0 to 10 VDC Proportional Analog Output

These Baratron® capacitance manometers feature a high-level 0-10 VDC analog output signal that is linear with pressure. This analog output can be interfaced with an MKS pressure controller, an MKS power supply/display instrument, or any instrument that meets these requirements. They are powered by a ±15 VDC input voltage.

15-pin D-subminiature Connector

Pin Description
2 Signal Output
5 Power Common
6 -15 VDC
7 +15 VDC
12 Signal Common
15 Chassis Ground

Accessories

Compatible Cables

Compare Description Drawings, CAD & Specs Avail. Price
RCB2000S-1-M1Manometer Cable, PDR2000 controller to 626, 627, 628 or 722 Manometers, DB15, 10 ft., RoHS, Shielded
$389
RCB2000S-1-M2Manometer Cable, PDR2000 controller to 626, 627, 628 or 722 Manometers, DB15, 20 ft, RoHS.
$609
100007557Manometer Cable, Connects 937 Controller and 626 Manometers, 50 ft.
$348
RCB258S-1-10Manometer Cable, 244 or 250 Controllers to 626 or 627 Manometers, 10 ft., RoHS, Shielded
$714
100007556Manometer Cable, 937B or 946 Controllers to 626 Manometers, 25 ft.
$220
RCB2000S-1-M3Manometer Cable, PDR2000 controller to 626, 627, 628 or 722 Manometers, DB15, 30 ft., RoHS
$557
100007555Manometer Cable, 937B or 946 Controllers to 626 or 627 Manometers, 10 ft.
$117

Power Supplies and Displays

Compare Description Drawings, CAD & Specs Avail. Price
industrial automation pressure input moduleAS11900G-03Pressure Input Module, 15 pin D-Sub Connector, 4 Channel
$1,519
pr4000b digital power supply and readoutPR4000BF2V3Digital Power Supply, Display, 2 Channel, RS232, ±24VDC, 1.0 Amp
$3,033
pr4000b digital power supply and readoutPR4000BF2V2Digital Power Supply, Display, 2 Channel, RS232, ±15VDC, 1.5 Amp
$2,982
pr4000b digital power supply and readoutPR4000BF5V2Digital Power Supply, Display, 2 Channel, RS485, ±15VDC, 1.5 Amp
$2,785
pr4000b digital power supply and readoutPR4000BF5V3Digital Power Supply, Display, 2 Channel, RS485, ±24VDC, 1.0 Amp
$2,785
pr4000b digital power supply and readoutPR4000BS2V2Digital Power Supply, Display, 1 Channel, RS232, ±15VDC, 1.5 Amp
$2,706
pr4000b digital power supply and readoutPR4000BS2V3Digital Power Supply, Display, 1 Channel, RS485, ±24VDC, 1.0 Amp
$2,729
pdr2000a two-channel digital power supply and readoutPDR2000AODigital Power Supply, Display, 2 Channels, RS232, ±15 VDC, 0.75 Amp
$999