628H 0.05-25,000 Torr, Heated (100°C) Absolute Baratron® Capacitance Manometers
Model: 628H13TBE1B
628H 0.05-25,000 Torr, Heated (100°C) Absolute Baratron® Capacitance Manometers
Model: 628H13TBE1B

Overview
Overview
The 628H13TBE1B Heated (100°C) Absolute Baratron® Capacitance Manometer features 1000 Torr Full Scale pressure measurement, a female 8 VCR type fitting, 15-pin D-subminiature electrical connector and vertical calibration. It is temperature controlled to 100°C, accurate to 0.25% of reading and includes updated temperature control electronics to provide superior long-term stability and repeatability. Based on established Baratron® capacitance manometer technology, the sensor's wetted surfaces are Inconel® for excellent resistance to corrosive gases. The contemporary stainless steel package provides a cleanroom-compatible product. The product is interchangeable with earlier Types 128 and 628 Baratron capacitance manometers and can be used with MKS power supplies, display units and pressure controllers, or the user's compatible power supply/readout devices.
Technical Specs
- TypeVacuum/pressure Transducer
- Measurement TypeAbsolute
- Sensor Temperature100°C
- Full Scale Range1000 Torr
- Accuracy0.25% of Reading
- Resolution0.001% of Full Scale
- Fitting Type8 VCR female
- Analog Output0-10 VDC
- Analog Connector15-pin D-sub with Thread Locks
- CalibrationVertical
- Zero Temperature Coefficient0.002% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Operating Temperature Range15-50°C
- Volume6.3 cc
- Warm-up Time2 hours
- Overpressure Limit45 psia (310 kPa) or 120% of Full Scale, whichever is greater
- Exposed MaterialsInconel
- Power Requirements±15 VDC ±5% @ 0.60 Amps (max.)
- IndicatorsNo
- ComplianceCE
Technical Specs
- TypeVacuum/pressure Transducer
- Measurement TypeAbsolute
- Sensor Temperature100°C
- Full Scale Range1000 Torr
- Accuracy0.25% of Reading
- Resolution0.001% of Full Scale
- Fitting Type8 VCR female
- Analog Output0-10 VDC
- Analog Connector15-pin D-sub with Thread Locks
- CalibrationVertical
- Zero Temperature Coefficient0.002% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Operating Temperature Range15-50°C
- Volume6.3 cc
- Warm-up Time2 hours
- Overpressure Limit45 psia (310 kPa) or 120% of Full Scale, whichever is greater
- Exposed MaterialsInconel
- Power Requirements±15 VDC ±5% @ 0.60 Amps (max.)
- IndicatorsNo
- ComplianceCE