e-Vision 2 General Purpose Residual Gas Analyzer
Model: E-VISION-2
e-Vision 2 General Purpose Residual Gas Analyzer
Model: E-VISION-2

Overview
Overview
The e-Vision 2 RGA is one of a new range of residual gas analysis products, from MKS Instruments, designed to meet all the traditional requirements for an RGA sensor but with data collection at speeds unachievable with previous generation technologies. The e-Vision 2 RGA is designed to provide maximum value for money. The e-Vision 2 is designed to collect data at millisecond speeds per data point even when measuring data over the full dynamic range of the RGA. This capability has been achieved without sacrificing any of the necessary robustness, reliability and support which have served to make MKS the world leader in RGA products over the widest range of applications - from semiconductor tools or particle accelerators to general industrial applications.
Technical Specs
- TypeResidual Gas Analyzer
- Measurement TechniqueMass Spectrometry
- Mass Range1-100 or 1-200 amu
- DetectorFaraday or Dual Faraday Microchannel Plate Electron Multiplier
- FilamentsTungsten or Thoria Coated Iridium
- SoftwareBuilt-in web applications allowing RGA control and data acquisition without installed software using web browser on any PC. Optional EasyView for Windows 2000, XP or Vista
- Filter length4 in. (100 mm)
- Maximum Analyzer Operating Pressure1e-4 Torr (1.3e-4 mbar)
- Ion Source Sensitivity2e-4 A/mbar
- Mass Stability±0.1 amu over 8 hours at stable ambient
- ResolutionBetter than 10% valley for peaks of equal height across mass range
- Bake Out Temperature250°C with electronics removed
- Operating Temperature200°C Faraday only with electronics 10 - 40°C, 150°C Multiplier with electronics 10 - 40°C and pressure <1e-8 mbar, 90°C Multiplier with electronics 10 - 40°C and pressure <1e-5 mbar
- Maximum Operating Conditions10 - 40°C, 80% RH (non condensing)
- Electronics Weight on Flange1.7 kg
- Power24 VDC, 2A external universal voltage supply (included)
- Data Acquisition MethodDedicated realtime acquisition processor
- Data Acquisition Speed<3 ms per point for analog scans
- Data Collection MethodsAnalog scanning, full mass range 8, 16 or 32 points/amu, Barchart scanning, Peak-jump collection of up to 15 peaks per scan
- Settling Time<20 ms
- Control MethodCE operating system processor with web-server interface
- Command StructureDocumented ASCII command protocols
- Electron Energy & Emission Current40 or 70 eV fixed (set in web configuration), 1 mA
- Filament ProtectionOpto-isolated input for filament protect or control with auto detection of presence of the jack plug as failsafe
- Communication10/100 Base-T Ethernet, static or automatically assigned IP addresses
- ComplianceCE
Technical Specs
- TypeResidual Gas Analyzer
- Measurement TechniqueMass Spectrometry
- Mass Range1-100 or 1-200 amu
- DetectorFaraday or Dual Faraday Microchannel Plate Electron Multiplier
- FilamentsTungsten or Thoria Coated Iridium
- SoftwareBuilt-in web applications allowing RGA control and data acquisition without installed software using web browser on any PC. Optional EasyView for Windows 2000, XP or Vista
- Filter length4 in. (100 mm)
- Maximum Analyzer Operating Pressure1e-4 Torr (1.3e-4 mbar)
- Ion Source Sensitivity2e-4 A/mbar
- Mass Stability±0.1 amu over 8 hours at stable ambient
- ResolutionBetter than 10% valley for peaks of equal height across mass range
- Bake Out Temperature250°C with electronics removed
- Operating Temperature200°C Faraday only with electronics 10 - 40°C, 150°C Multiplier with electronics 10 - 40°C and pressure <1e-8 mbar, 90°C Multiplier with electronics 10 - 40°C and pressure <1e-5 mbar
- Maximum Operating Conditions10 - 40°C, 80% RH (non condensing)
- Electronics Weight on Flange1.7 kg
- Power24 VDC, 2A external universal voltage supply (included)
- Data Acquisition MethodDedicated realtime acquisition processor
- Data Acquisition Speed<3 ms per point for analog scans
- Data Collection MethodsAnalog scanning, full mass range 8, 16 or 32 points/amu, Barchart scanning, Peak-jump collection of up to 15 peaks per scan
- Settling Time<20 ms
- Control MethodCE operating system processor with web-server interface
- Command StructureDocumented ASCII command protocols
- Electron Energy & Emission Current40 or 70 eV fixed (set in web configuration), 1 mA
- Filament ProtectionOpto-isolated input for filament protect or control with auto detection of presence of the jack plug as failsafe
- Communication10/100 Base-T Ethernet, static or automatically assigned IP addresses
- ComplianceCE